Fixing the postbuild order problem of the upstream/downstream solution i wrote

Some days ago i wrote a post about how to get the overall status in the upstream job from the downstream jobs in Hudson or Jenkins (https://fatalfailure.wordpress.com/2011/06/14/jenkins-hudson-getting-the-overall-status-in-the-upstream-job-from-the-downstream-jobs/).

A user (v22 ) test my code and had some problems, and actually, there is a problem.

As i said in the comment reply, there is a problem in the execution order of the post build actions, this is not deterministic and depends on how the job configuration is stored in a XML file located in the master node.

The relationship between the upstream jobs and the downstream jobs is ready when the fingerprints are recorded. This action is done on a post build action, like the Groovy execution. If the Groovy execution is performed before the fingerprint recording, there is not upstrem job set yet, therefore the Groovy code fails.

I proposed in that reply a workaround to change the order execution of the post build actions, but this is not working as i expected, so there is not a way to force the Groovy execution after the fingerprint recording.

There is an open ticket in the Jenkins and Hudson issue tracker to add a way to specify the post build actions executions: https://issues.jenkins-ci.org/browse/JENKINS-7408

But everything has a solution, and a solution that always works 😉

Continue reading